Water-cooled screw chiller

Chuanyang Refrigeration’s cabinet‑type water‑cooled chillers are widely used in industrial applications such as chemical processing, electronics, plastics, batteries, food production, pharmaceuticals, printing, and machining to provide stable temperature control and cooling. They help boost your product output while safeguarding your production equipment. Customizable low‑temperature models are available, with chilled water temperatures ranging from 0°C to –30°C and adjustable settings.

Detailed description

Product Overview
Chuanyang Refrigeration’s water-cooled screw chillers are widely used for constant‑temperature cooling in industrial applications such as chemical processing, electronics, plastics, batteries, food production, pharmaceuticals, printing, and machining. They help boost your product output while safeguarding your production equipment. Customizable low‑temperature models are available, with chilled water temperatures ranging from 0°C to –30°C and adjustable settings.

 

Unit Features:
1. Electrical enclosure: Constructed from high-strength steel sheet with a powder-coated finish, it is manufactured using state-of-the-art, patented precision machining to ensure resistance to rust even when exposed to acidic or alkaline gases.
2. Compressors: Equipped with internationally renowned brands—Germany’s Bitzer and Taiwan’s Hanbell series—offering high cooling capacity and quiet operation.
3. Condenser/evaporator: Equipped with condensers and evaporators from renowned brands that hold national pressure vessel certification.
4. Automatic adjustment based on Level 4 or zero‑energy efficiency, saving both energy and hassle.
5. Equipped with comprehensive safety protection and indication functions, ensuring the unit operates safely and reliably.
6. Protection rating: IP54.
7. The chiller’s water system is pressure‑tested at 0.9–1.0 MPa, while the refrigerant system is tested at 3.5–4.0 MPa, both undergoing high‑intensity pressure testing.
8. Equipped with Siemens and Taiwan Bangpu controllers, featuring the MODBUS‑485 protocol, enabling remote monitoring via network connectivity (optional).
9. Fully Chinese-language human-machine interface, with dynamic monitoring, real-time adjustment, and a sleek, sophisticated design.
10. After being calibrated on an automated constant-temperature test bench, the unit is shipped from the factory, ensuring optimal performance and enabling 24-hour continuous operation.
 

 

Model and Basic Specifications

Model/Specifications

Cooling capacity

Compressor input power

KW

Chilled water flow rate

m 3/h

Reference external dimensions

L×W×H (mm)

KW

Kcal/hr

CYZL-40WN

132

113520

30

24

1900×600×1500

CYZL-50WN

165

141900

37.5

30

1900×600×1500

CYZL-60WN

198

170280

45

36

2300×600×1550

CYZL-70WN

231

198660

52.5

42

2300×600×1550

CYZL-80WN

264

227040

60

48

2600×650×1600

CYZL-90WN

297

255420

67.5

54

2600×650×1600

CYZL-100WN

330

312180

75

60

2600×650×1600

CYZL-110WN

363

312180

82.5

66

3100×650×1700

CYZL-120WN

396

340560

90

72

3300×700×1750

CYZL-130WN

429

368940

97.5

78

3300×700×1750

CYZL-140WN

462

397320

105

84

3500×700×1800

CYZL-150WN

495

425700

112

90

3500×700×1800

CYZL-160WN

528

454080

120

96

3800×1000×1800

CYZL-170WN

594

510840

135

108

3900×1000×1800

CYZL-200WN

660

567600

150

120

3900×1000×1800

CYZL-210WN

726

624360

165

132

4400×1100×1900

CYZL-250WN

792

681120

180

144

4600×1200×2000

CYZL-300WN

990

851400

225

180

5000×1200×2050

CYZL-350WN

1188

1021680

270

216

5500×1250×2100

CYZL-400WN

1320

1135200

300

240

6000×1300×2200

Note:
1. The cooling capacity is calculated based on inlet and outlet water temperatures of 12°C/7°C, a condenser water temperature of 40°C, and a fouling factor of 0.088 m²·°C/kW.
2. Specifications, parameters, and dimensions are subject to change due to product improvements; no further notice will be provided.

 

Related products

Air-cooled chiller

Chuanyang Refrigeration’s cabinet‑type air‑cooled chillers are widely used in industrial applications such as chemical processing, electronics, plastics, batteries, food production, pharmaceuticals, printing, and machining to provide stable temperature control and cooling. They help boost your product output and safeguard your production equipment. Customizable as low‑temperature models, with outlet water temperatures ranging from 0°C to –30°C and adjustable settings.

View Details >

Water-cooled screw chiller

Chuanyang Refrigeration’s cabinet‑type water‑cooled chillers are widely used in industrial applications such as chemical processing, electronics, plastics, batteries, food production, pharmaceuticals, printing, and machining to provide stable temperature control and cooling. They help boost your product output while safeguarding your production equipment. Customizable low‑temperature models are available, with chilled water temperatures ranging from 0°C to –30°C and adjustable settings.

View Details >

Low-temperature air conditioner

Chuanyang Refrigeration’s low-temperature chillers are designed to provide precise and rapid environmental temperature control for chips, modules, integrated circuit boards, electronic components, and more. They serve as an alternative to liquid nitrogen, offering fast cooling for localized heat sources. These units also supply a reliable cold source for testing electrical performance, reliability, and aging characteristics. Outlet air temperature: -50°C to -130°C.

View Details >

Water-cooled chiller

Chuanyang Refrigeration’s cabinet‑type water‑cooled chillers are widely used in industrial applications such as chemical processing, electronics, plastics, batteries, food production, pharmaceuticals, printing, and machining to provide stable temperature control and cooling. They help boost your product output while safeguarding your production equipment. Customizable low‑temperature models are available, with chilled water temperatures ranging from 0°C to –30°C and adjustable settings.

View Details >

Contact Us

If you’re interested in collaborating, please contact us today—we’ll get back to you as soon as possible!




MAKE SURE THE HEATER WORKS IN VERY COLD AREAS

A deeper look into the technology and testing procedures

CAN COLDKING HEATERS BE OPERATED WHILE DRIVING?

Yes! Heating while driving is allowed worldwide for all our heaters! This way you can have a cosy and warm interior already when arriving at your holiday destination.

The technology of diesel heaters made big steps forward since the first heaters were introduced. Together with specially configured motorhome heaters, ColdKing provides silent application kits whose various accessories eliminate all possible disturbances (i.e. exhaust silencer, ultra-silent pump, etc.), for your comfort and the comfort of your campground neighbour.

ColdKing parking heaters do not require a catalyst

ColdKing heaters do not need a catalyser thanks to the very effective burning process. The exhaust values of our heaters are already on a very low level within the legal requirements.

Frequently Asked Questions

Our FAQ section helps you quickly learn about our products and services.

Can I become your agent on certain market?

For exclusive agents on certain market, we have minimum order requirement for all year and down payment for the whole year orders. If order quantity is over certain quantity, we will customize your own model. Please contact our salesmen for more details.

Do I need to buy other parts after I receive the parking air conditioner?

It’s a whole package with all parts needed. For rooftop parking air conditioners, Freon is prefilled, so all you need to do is install and connect it to battery. For split air conditioners without Freon, all you need to do is ask a mechanic to install and fill Freon at suggested amount.

How Long Can Parking Air Conditioner Keep Working With Battery Of My Vehicle?

It depends on the capacity of battery equipped by your vehicle, working mode of air conditioner you select and the target temperature you set. Kindly remind that once the target temperature is reached, the compressor will stop working no matter which working mode is set by users.

Example 1: 12V/100Ah battery, strong cooling mode, compressor works in 50% of time, can sustain around 2.8h (100Ah/70A/50%=2.8) of running.

Example 2: 24V/180Ah battery, standard cooling mode, compressor works in 70% of time, can sustain around 9.5h (180Ah/27A/70%=9.5) of running.

What is the power of the heater?

The power of different heater models varies, generally ranging from 2000 to 5000 watts. You can view the power parameters of specific models on the product details page.

What is the service life of the heater?

Under normal use and maintenance, the service life of the heater can reach 10 years. We also provide comprehensive after - sales maintenance services to ensure your usage experience.

Is the heater safe?

The product has multiple safety protection functions, such as overheating protection and short - circuit protection, to ensure safety during use. At the same time, all products have passed strict safety tests and meet international safety standards.

Factory environment

Factory environment

Factory environment

Factory environment

Factory environment

Factory environment

Factory environment

Factory environment

Factory environment

Factory environment

Factory environment

Factory environment

Factory environment

Factory environment

Factory environment

Factory environment

< 1 >